• Power Testing Products Supply & Volt-Ampere Characteristic CT Vt Anlyzer CT PT Calibrator
  • Power Testing Products Supply & Volt-Ampere Characteristic CT Vt Anlyzer CT PT Calibrator
  • Power Testing Products Supply & Volt-Ampere Characteristic CT Vt Anlyzer CT PT Calibrator
  • Power Testing Products Supply & Volt-Ampere Characteristic CT Vt Anlyzer CT PT Calibrator
  • Power Testing Products Supply & Volt-Ampere Characteristic CT Vt Anlyzer CT PT Calibrator
  • Power Testing Products Supply & Volt-Ampere Characteristic CT Vt Anlyzer CT PT Calibrator

Power Testing Products Supply & Volt-Ampere Characteristic CT Vt Anlyzer CT PT Calibrator

After-sales Service: 1 Year
Warranty: 1 Year
Max Diameter of Workpiece: <500mm
Mass Scope of Workpiece: <900kg
Type: Universal Testing Machine
Maxcapacity: <1000KN
Customization:
Manufacturer/Factory, Trading Company
Gold Member Since 2021

Suppliers with verified business licenses

Hubei, China
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Self-branded
The supplier has 2 Self-brands, check the Audit Report for more information
100% Finished Products Inspection
The supplier inspects 100% of finished products.
R&D Capabilities
The supplier has 10 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (25)

Basic Info.

Model NO.
HDHG- 108
Accuracy Grade
0.5
Load Way
Electronic Load
Loading Method
Static Load
Display
Digital
Control
Manual Control
Weight
0-100Kg
Power Source
AC220V
Oil Cylinder Position
Top
Excitation Voltage
1~10kv
Excitation Measurement Accuracy
≤0.2%
Secondary Resistance
0.1~1000Ω
Secondary Load
5va~1000va
Power Factor
0.1-1
Power Supply
220V 50Hz
Transport Package
Wooden Box
Origin
China
HS Code
9030820000
Production Capacity
2000/Year

Product Description


HDHG- 108 CT PT Tester

General Information


CT PT Tester is designed for automatically test transformer characteristics of protection type, metering type, GIS bushing, zero sequence.

Features
 
  1. Support for detecting the parameter of CT and PT in steady state and instantaneous state
  2. Adopt advance the theory of DC method and variable frequency method .
  3. Support battery power supply
  4. Support RS232 interface and can connect to PC
  5. With the function of comprehensive detection and item detection for onsite operation .
  6. Quick detection for second actual load and power factor of transformer.
  7. Can detect PT no-load loss and no-load current
  8. Automatically detect 5% and 10% error curve and composite error
  9. Automatically given knee point value and Kafl
  10. Automatically calculate the limit factor and load parameter of transformer under the different parameter.
  11. Detect the any ratio and resistance at any temperature.
  12. With the micro-printer for printing measurement data in the field
  13. Adopts TFT colorful LCD touch display screen and easy operation.
  14. Built-in recorder and save 10000 group measurement data .It won't lost after power off.
  15. Equipped with data analysis software. It can generate the detection reporter by PC.
  16. Automatically display time, temperature , humidity etc environment information.l
  17. It is light weight and suitable for onsite testing.

Technical parameter
 
Working Power AC220V±10% ,50Hz
Output 0~100Vrms,5Arms(equivalent calculation peak value 20A)

 
Excitation Voltage 1~10KV
Excitation Measurement Accuracy ≤0.2%
Secondary Resistance Range/Accuracy 0.1~1000Ω / ≤0.2%
Secondary Load Range/Accuracy 5VA~1000VA / ≤0.2%
Power Factor Range  0.1-1
Phase Position Measurement Range/Accuracy 0-360°/ ±0.05°
PT Turn Ratio Range/Accuracy 1-1000/0.05%   1000-10000/0.5%
CT Turn Ratio Range/Accuracy 1-2000/0.05%   2000-50000/0.5%
Working Temperature Temperature -20ºC ~ 50ºC; Humidity ≤90%,
Altitude:≤2000m
Size Dimension:280mm × 246mm × 158mm;  Weight ≤5Kg

Main Parameter
 
CT PT
  1. Volt-ampere characteristic curve (calculate knee point value)
  2. Error curve(5% and 10%)
  3. Any turn ratio measurement
  4. Polarity Judgement
  5. Second winding resistance measurement at any temperature.
  6. Second actual load measurement
  7. Power factor measurement
  8. Core demagnetization
  9. Angel Error and Turn Ratio Error Measurement
  10. Environment temperature , humidity and altitude measurement
  11. Meter security factor (FS)
  12. Accuracy limit factor(ALF)
  13. Composite error
  1. Volt-ampere characteristic curve (calculate knee point value)
  2. Any turn ratio measurement
  3. Polarity Judgement
  4. Second winding resistance measurement at any temperature.
  5. Second actual load measurement
  6. Power factor measurement
  7. Core demagnetization
  8. Angel Error and Turn Ratio Error Measurement
  9. Environment temperature , humidity and altitude measurement
  10. No-load loss
  11. No-load current

Power Testing Products Supply &amp; Volt-Ampere Characteristic CT Vt Anlyzer CT PT CalibratorPower Testing Products Supply &amp; Volt-Ampere Characteristic CT Vt Anlyzer CT PT CalibratorPower Testing Products Supply &amp; Volt-Ampere Characteristic CT Vt Anlyzer CT PT CalibratorPower Testing Products Supply &amp; Volt-Ampere Characteristic CT Vt Anlyzer CT PT CalibratorPower Testing Products Supply &amp; Volt-Ampere Characteristic CT Vt Anlyzer CT PT CalibratorPower Testing Products Supply &amp; Volt-Ampere Characteristic CT Vt Anlyzer CT PT CalibratorPower Testing Products Supply &amp; Volt-Ampere Characteristic CT Vt Anlyzer CT PT CalibratorPower Testing Products Supply &amp; Volt-Ampere Characteristic CT Vt Anlyzer CT PT Calibrator

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Plant Area
>2000 square meters
Management System Certification
ISO 9001, ISO 14001