After-sales Service: | 1 Year |
---|---|
Warranty: | 1 Year |
Type: | Storage Battery Tester |
Customization: |
---|
Shipping Cost:
Estimated freight per unit. |
about shipping cost and estimated delivery time. |
---|
Payment Method: | |
---|---|
Initial Payment Full Payment |
Currency: | US$ |
---|
Return&refunds: | You can apply for a refund up to 30 days after receipt of the products. |
---|
Suppliers with verified business licenses
HDGC3982 Series Battery Discharging Tester(Wide Voltage) | ||||||||
Type: HDGC3982- | H8030050 | H8010620 | H8010630 | H8011310 | H8082605 | H8082606 | H8174503 | H8306003 |
Output | ||||||||
Discharge Voltage Range | 10~300V | 10~60V | 10-132V | 88-264V | 176-456V | 300-600V | ||
Discharge Current Range | 10~19V:0~50A 19~180V:0~100A 180~300V:0~50A |
0~200A | 0~300A | 0~100A | 0~50A | 0~60A | 0~30A | 0~30A |
Output power | ≤18KW | ≤12KW | ≤18KW | ≤13.2KW | ≤13.2KW | ≤15.8KW | ≤13.6KW | ≤18KW |
Group voltage resolution | 0.1V | |||||||
Group voltage accuracy | ±0.5%FS+0.1V(Full scale) | |||||||
Cell Voltage Measurement Range | 1.00V~16.00V,Resolution: 0.01V (the resolution can be accurate to 0.001V through the software view) | |||||||
Cell Voltage Measurement Accuracy | ±0.1%FS | |||||||
Current measurement accuracy | ±1%FS+0.1A(Full scale) | |||||||
Battery capacity check range | 0~1000Ah | 0~2000Ah | 0~3000Ah | 0~1000Ah | 0~500Ah | 0~500Ah | 0~300Ah | 0~300Ah |
Display | ||||||||
Display Material | Resistive Touchscreen | |||||||
Display Mode | 7-Inch LCD true color, resolution: 1024*800 | |||||||
Working Mode&Data | ||||||||
Working mode | Single main unit / parallel master mode / parallel slave mode / remote controlled mode / Quick Test | |||||||
Data storage capacity | Internal: 16Gbit TF card | |||||||
Data communication | RS485*3,USB*1,RF433 | |||||||
Protection Performance | ||||||||
Battery side protection | Under-voltage, over-voltage, over-current, over-temperature, short-circuit, reverse connection protection | |||||||
Audible and visual alarm | Reverse polarity, cut-off condition completion triggers LCD prompt, beep warning | |||||||
Emergency stop protection | External open circuit breaker for emergency shutdown protection | |||||||
Power Supply | ||||||||
Voltage | Single-phase3-Wire AC220V (-20%-+30%), frequency: 45-65Hz; | |||||||
Withstand voltage | Input-shell: 2200Vdc 1min / Input-output: 2200Vdc 1min / Output-shell: 700Vdc 1min |
Suppliers with verified business licenses