Customization: | Available |
---|---|
After-sales Service: | 1 Year |
Warranty: | 1 Year |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Suitable Battery | DC 220V Battery Pack |
Model No. | HDGC3980 |
Discharge current | 0~100A |
Discharge Voltage | DC 176-270V |
Working mode | Single main unit, parallel master mode, parallel slave mode, and remote controlled mode |
Protection performance | Over-voltage protection, under-voltage stop, over-current protection, reverse wiring protection, 65ºC over-temperature protection, LCD prompt and buzzer alarm |
Cell voltage collection (optional) | Multi-band RF wireless module for communication distance of more than 100m, compatible with 2V/4V/6V/12V cell monitor module , 1-25 groups of RF wireless monitoring modules up to 300 batteries, and single wireless monitoring module for monitoring 12 cells |
Control precision | Discharge current≤±1%; group voltage≤±0.1%; cell voltage≤±0.5% |
PC communication | RS485 interface, USB interface |
Work Environment | |
Heat radiation | Forced air cooling |
Temperature | Working rage: -5-50ºC Storage temperature: -40-70ºC |
Humidity | Relative humidity 0-90% (40±2ºC) |
Elevation | Below 4,000m |
Noise | <75dB |
Working Power Supply | |
Voltage | Power supply: single-phase AC220V (-20%-+30%), frequency: 45-65Hz; |
Electric strength test | Input-shell: 2200Vdc 1min Input-output: 2200Vdc 1min Output-shell: 700Vdc 1min |
Safety | Compliance with EN610950 |
HDGC3980 Battery Discharge Tester can be used as the discharge load in the battery off-line state to realize the constant discharge at the set value by regulating continuously the discharge current. When discharging, the tester will automatically stop discharging when the voltage on the battery group terminal or the cell falls to the set lower limit value, or when the set discharging time is out, or when it reaches the set discharging capacity. Battery Discharge Tester can records all valuable and continuous real-time data during the discharge process.
This tester system is simple, safe and accurate for monitoring voltage of cells adopting wireless connection.
1. Product Panel
2. Product Data Management