HDGC3970 Series Battery Charging Tester | ||||||||||||||||||
Type: HDGC3970-CDY | 04810 | 04820 | 04830 | 08020 | 08040 | 15010 | 15020 | 22001 | 22002 | 22006 | 22010 | 38004 | 38006 | 48003 | 48005 | 100002 | 100003 | 100004 |
Output | ||||||||||||||||||
Charging Voltage Range | 32-60V | 40-100V | 60-200V | 190-270V | 50-300V | 300-500V | 400-630V | 600-1000V | ||||||||||
Charging Current Range | 0~100A | 0~200A | 0~300A | 0~200A | 0~400A | 0~100A | 0~200A | 0~10A | 0~20A | 0~60A | 0~100A | 0~40A | 0~60A | 0~30A | 0~50A | 0~20A | 0~30A | 0~40A |
Output power | ≤6KW | ≤12KW | ≤18KW | ≤20KW | ≤40KW | ≤20KW | ≤40KW | <3KW | ≤6KW | ≤18KW | ≤30KW | ≤20KW | ≤30KW | ≤20KW | ≤30KW | ≤20KW | ≤30KW | ≤40KW |
Group voltage resolution | 0.1V | |||||||||||||||||
Group voltage accuracy | ±0.5%FS+0.1V(Full scale) | |||||||||||||||||
Current measurement accuracy | ±1%FS+0.1A(Full scale) | |||||||||||||||||
Battery capacity check range | 0-1000Ah | 0-2000Ah | 0~3000Ah | 0-2000Ah | 0-400Ah | 0-1000Ah | 0-200Ah | 0-100Ah | 0-200Ah | 0-600Ah | 0-1000Ah | 0-400Ah | 0-600Ah | 0-300Ah | 0-500Ah | 0-200Ah | 0-300Ah | 0-400Ah |
Display | ||||||||||||||||||
Display Material | Resistive Touchscreen | |||||||||||||||||
Display Mode | 7-Inch LCD true color, resolution: 1024*800 | |||||||||||||||||
Working Mode&Data | ||||||||||||||||||
Working mode | Single main unit / parallel master mode / parallel slave mode / remote controlled mode / Quick Test | |||||||||||||||||
Data storage capacity | Internal: 16Gbit TF card | |||||||||||||||||
Data communication | RS485*3,USB*1,RF433 | |||||||||||||||||
Protection Performance | ||||||||||||||||||
Battery side protection | Under-voltage, over-voltage, over-current, over-temperature, short-circuit, reverse connection protection | |||||||||||||||||
Audible and visual alarm | Reverse polarity, cut-off condition completion triggers LCD prompt, beep warning | |||||||||||||||||
Emergency stop protection | External open circuit breaker for emergency shutdown protection | |||||||||||||||||
Power Supply | ||||||||||||||||||
Voltage | Single-phase3-Wire AC220V (-20%-+30%), frequency: 45-65Hz; | |||||||||||||||||
Withstand voltage | Input-shell: 2200Vdc 1min / Input-output: 2200Vdc 1min / Output-shell: 700Vdc 1min | |||||||||||||||||
With Cell Monitoring Model(Optional) | ||||||||||||||||||
Cell Voltage Measurement Range | 1.00V~16.00V,Resolution: 0.01V (the resolution can be accurate to 0.001V through the software view) | |||||||||||||||||
Cell Voltage Measurement Accuracy | ±0.1%FS |