48V 100A Battery Load Tester Battery Discharge Test DC Load Bank for Checking Battery Real Capacity in Power Plant, Data Center and Telecom

Product Details
Customization: Available
After-sales Service: 1 Year
Warranty: 1 Year
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company
Secured Trading Service
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Self-branded
The supplier has 3 Self-brands, check the Audit Report for more information
100% Finished Products Inspection
The supplier inspects 100% of finished products.
R&D Capabilities
The supplier has 10 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (25)
  • 48V 100A Battery Load Tester Battery Discharge Test DC Load Bank for Checking Battery Real Capacity in Power Plant, Data Center and Telecom
  • 48V 100A Battery Load Tester Battery Discharge Test DC Load Bank for Checking Battery Real Capacity in Power Plant, Data Center and Telecom
  • 48V 100A Battery Load Tester Battery Discharge Test DC Load Bank for Checking Battery Real Capacity in Power Plant, Data Center and Telecom
  • 48V 100A Battery Load Tester Battery Discharge Test DC Load Bank for Checking Battery Real Capacity in Power Plant, Data Center and Telecom
  • 48V 100A Battery Load Tester Battery Discharge Test DC Load Bank for Checking Battery Real Capacity in Power Plant, Data Center and Telecom
  • 48V 100A Battery Load Tester Battery Discharge Test DC Load Bank for Checking Battery Real Capacity in Power Plant, Data Center and Telecom
Find Similar Products

Basic Info.

Model NO.
HDGC3980
Type
Storage Battery Tester
Test Region
Charge and Discharge
Application
Lead-acid Battery
Customized
Customized
Discharge Voltage
DC 48-60V
Discharge Current
0~100A
Power Supply
220V 50Hz
Model Type
Hdfd-4810
Cooling
Force Air Cooling
PC Communication
RS485 or USB
Working Temperature
-5-50ºC
Transport Package
Wooden Box with Foam Inside
Trademark
HD Power
Origin
Made in China
HS Code
9030899090
Production Capacity
800/Month

Packaging & Delivery

Package Size
530.00cm * 280.00cm * 360.00cm
Package Gross Weight
25.000kg

Product Description

General information

HDGC-3980  Battery Discharge Tester can be used as the discharge load in the battery off-line state to realize the constant discharge at the set value by regulating continuously the discharge current.

When discharging, the tester will automatically stop discharging when the voltage on the battery group terminal or the cell falls to the set lower limit value, or when the set discharging time is out, or when it reaches the set discharging capacity. Battery Discharge Tester can records all valuable and continuous real-time data during the discharge process.



Features

1.PTC ceramic resistor is adopted to avoid the red heat phenomenon for a safer discharge process.

2.Cell monitoring module is performed the voltage commission by remote radio wireless communication mode, it can set up to four unique frequency brands.

3.Wireless acquisition box can monitor each cell for monitoring the whole process of battery series. There are three data monitoring methods.

4.Each tester can monitor 25 cell monitoring  mode , every cell monitoring mode can connect 12 battery ,monitoring in total of 300 battery. 

5.Cell voltage value can be displayed by sliding table and sliding bar chart and searched by two data .

6.Connected with USB interface,the data of the discharge process can be record to U disk and transformed to PC by U disk . PC data manage software can analyze the discharge process and generate the corresponding data for more convenient storage .

7.Intelligent SCM ARM control, 7inch 1024*600 LCD screen , capacitive touch operation, built in English menu, simple and clear operation menu.

8.Automatic self-protection stop function,over-heat protection,over voltage protection,over current protection and reverse connection protection,alarm prompt is displayed on the screen once it appears any issue, air circuit breaker automatically cut off.

9.It can perform on-line compensated charge/discharge, and can also carry on discharge test for on-line working storage battery by connection  external current clamp sensor,which is convenient for measurement work. 

10. RS485 remote control charge , discharge and activation functions .

11. It has the function of charge, discharge and activation with muti machine parallel mode by only operating in the display screen of the parallel  instrument with parameters as the master. 



Technical Parameter
 
Suitable Battery DC 48V
Model No. HDGC3980
Discharge current 0~100A
Discharge Voltage DC 48-60V
Working mode Single main unit, parallel master mode, parallel slave mode, and remote controlled mode
Protection performance Over-voltage protection, under-voltage stop, over-current protection, reverse wiring protection, 65ºC over-temperature protection, LCD prompt and buzzer alarm
Cell voltage collection (optional) Multi-band RF wireless module for communication distance of more than 100m, compatible with 2V/4V/6V/12V cell monitor module , 1-25 groups of RF wireless monitoring modules up to 300 batteries, and single wireless monitoring module for monitoring 12 cells
Control precision Discharge current≤±1%; group voltage≤±0.1%; cell voltage≤±0.5%
PC communication RS485 interface, USB interface
Work Environment
Heat radiation Forced air cooling
Temperature Working rage: -5-50ºC  Storage temperature: -40-70ºC
Humidity Relative humidity 0-90% (40±2ºC)
Elevation Below 4,000m
Noise <75dB
Working Power Supply
Voltage Power supply: single-phase AC220V (-20%-+30%), frequency: 45-65Hz;
Electric strength test Input-shell: 2200Vdc 1min
Input-output: 2200Vdc 1min
Output-shell: 700Vdc 1min
Safety Compliance with EN610950
48V 100A Battery Load Tester Battery Discharge Test DC Load Bank for Checking Battery Real Capacity in Power Plant, Data Center and Telecom48V 100A Battery Load Tester Battery Discharge Test DC Load Bank for Checking Battery Real Capacity in Power Plant, Data Center and Telecom48V 100A Battery Load Tester Battery Discharge Test DC Load Bank for Checking Battery Real Capacity in Power Plant, Data Center and Telecom48V 100A Battery Load Tester Battery Discharge Test DC Load Bank for Checking Battery Real Capacity in Power Plant, Data Center and Telecom48V 100A Battery Load Tester Battery Discharge Test DC Load Bank for Checking Battery Real Capacity in Power Plant, Data Center and Telecom48V 100A Battery Load Tester Battery Discharge Test DC Load Bank for Checking Battery Real Capacity in Power Plant, Data Center and Telecom48V 100A Battery Load Tester Battery Discharge Test DC Load Bank for Checking Battery Real Capacity in Power Plant, Data Center and Telecom48V 100A Battery Load Tester Battery Discharge Test DC Load Bank for Checking Battery Real Capacity in Power Plant, Data Center and Telecom

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier