DC10-600V / 0-100A Battery Load Unit Lead Acid Battery Capacity Tester DC Load Bank Wide Voltage with Cell Monitoring Model
Reference FOB Price: US $5,300.00-7,600.00 / Piece
Min. Order: 1 Piece
After-sales Service: 1 Year
Warranty: 1 Year
Type: Storage Battery Tester
DC10-600V / 0-100A Battery Load Unit Lead Acid Battery Capacity Tester DC Load Bank Wide Voltage with Cell Monitoring Model pictures & photos
  • DC10-600V / 0-100A Battery Load Unit Lead Acid Battery Capacity Tester DC Load Bank Wide Voltage with Cell Monitoring Model
  • DC10-600V / 0-100A Battery Load Unit Lead Acid Battery Capacity Tester DC Load Bank Wide Voltage with Cell Monitoring Model
  • DC10-600V / 0-100A Battery Load Unit Lead Acid Battery Capacity Tester DC Load Bank Wide Voltage with Cell Monitoring Model
  • DC10-600V / 0-100A Battery Load Unit Lead Acid Battery Capacity Tester DC Load Bank Wide Voltage with Cell Monitoring Model
  • DC10-600V / 0-100A Battery Load Unit Lead Acid Battery Capacity Tester DC Load Bank Wide Voltage with Cell Monitoring Model
  • DC10-600V / 0-100A Battery Load Unit Lead Acid Battery Capacity Tester DC Load Bank Wide Voltage with Cell Monitoring Model
Basic Info
Model NO.
HDGC3982-HT8060050
Test Region
Charge and Discharge
Application
Lead-acid Battery
Customized
Customized
Discharge Current
0-100A/0-50A
Discharge Voltage
DC 0-600V
Display
7 Inch Color LCD Display
Power Supply
220V 45-65Hz
Suitable Battery
0-600V Battery Group
PC Communication
RS485 Interface, USB Interface
Temperature
-5-50ºC
Net Weight
63kg
Tester Size
630*390*966mm
Safety
Compliance with En610950
Package
Woodel Box
Cooling
Air Cooling
Communication
RS 485 or USB
Brand
HD Power
Optional Function
Cell Battery Monitor
Transport Package
Wooden Box with Foam Inside
Trademark
HD Power
Origin
Made in China
HS Code
9030899090
Production Capacity
800/Month
Product Description
 
HDGC3982 Series Battery Discharging Tester(for 0-600V Battery Group)
Type: HDGC3982-HT8060050
Output
Discharge Voltage Range0~600V
Discharge Current Range0~300V:100A
300~600V:50A
Output power≤30KW
Group voltage resolution0.1V
Group voltage accuracy±0.5%FS+0.1V(Full scale)
Cell Voltage Measurement Range1.00V~16.00V,Resolution: 0.01V (the resolution can be accurate to 0.001V through the software view)
Cell Voltage Measurement Accuracy±0.1%FS
Current measurement accuracy±1%FS+0.1A(Full scale)
Battery capacity check range0~1000Ah
Display
Display MaterialResistive Touchscreen
Display Mode7-Inch LCD true color, resolution: 1024*800
Working Mode&Data
Working modeSingle main unit / parallel master mode / parallel slave mode / remote controlled mode / Quick Test
Data storage capacityInternal: 16Gbit TF card
Data communicationRS485*3,USB*1,RF433
Protection performance
Battery side protectionUnder-voltage, over-voltage, over-current, over-temperature, short-circuit, reverse connection protection
Audible and visual alarmReverse polarity, cut-off condition completion triggers LCD prompt, beep warning
Emergency stop protectionExternal open circuit breaker for emergency shutdown protection
Power Supply
VoltageSingle-phase3-Wire  AC220V (-20%-+30%), frequency: 45-65Hz;
Withstand voltageInput-shell: 2200Vdc 1min / Input-output: 2200Vdc 1min / Output-shell: 700Vdc 1min

Product Profile
HDGC3982 Battery Discharge Capacity Tester can be used as the discharge load in the battery off-line state to realize the constant discharge at the set value by regulating continuously the discharge current.
When discharging, the tester will automatically stop discharging when the voltage on the battery group terminal or the cell falls to the set lower limit value, or when the set discharging time is out, or when it reaches the set discharging capacity. Battery Discharge Tester can records all valuable and continuous real-time data during the discharge process.
Wide voltage series battery pack discharge capacity tester is specially developed independently for DC maintenance, covering multiple voltage battery pack maintenance, multi-purpose.
DC10-600V / 0-100A Battery Load Unit Lead Acid Battery Capacity Tester DC Load Bank Wide Voltage with Cell Monitoring Model

Features
1.Wide voltage and high current design: a single unit can fulfill the discharge test of battery packs with multiple voltage ranges. One machine is multi-purpose.
2.PTC ceramic resistor is adopted to avoid the red heat phenomenon for a safer discharge process .
3.Intelligent SCM ARM control, 7inch 1024*600 LCD screen , capacitive touch operation, built in  English menu, simple and clear operation menu.
4.Automaticself-protection stop function, over-heat protection ,over voltage protection , over current protection and reverse connection protection ,alarm prompt is displayed on the screen once it appears any issue, air circuit breaker automatically cut off .
5.It can set discharge terminationcondition including cell low voltage,whole group voltage low/high, charge current low, charge/discharge time , charge/discharge capacity .When any condition can be met, the instrument can stop automatically testing with buzz sound and record the stop reason at the same time.
6.Estimation of the remaining capacity of the battery by a quick discharge of 3-5 minutes .
7.Cell voltage wireless monitoring function, Compatible with 2V/6V/12V cell voltage monitoring,each wireless monitoring module can simultaneously monitor 12 cells.



DC10-600V / 0-100A Battery Load Unit Lead Acid Battery Capacity Tester DC Load Bank Wide Voltage with Cell Monitoring ModelDC10-600V / 0-100A Battery Load Unit Lead Acid Battery Capacity Tester DC Load Bank Wide Voltage with Cell Monitoring ModelDC10-600V / 0-100A Battery Load Unit Lead Acid Battery Capacity Tester DC Load Bank Wide Voltage with Cell Monitoring ModelDC10-600V / 0-100A Battery Load Unit Lead Acid Battery Capacity Tester DC Load Bank Wide Voltage with Cell Monitoring ModelDC10-600V / 0-100A Battery Load Unit Lead Acid Battery Capacity Tester DC Load Bank Wide Voltage with Cell Monitoring ModelDC10-600V / 0-100A Battery Load Unit Lead Acid Battery Capacity Tester DC Load Bank Wide Voltage with Cell Monitoring ModelDC10-600V / 0-100A Battery Load Unit Lead Acid Battery Capacity Tester DC Load Bank Wide Voltage with Cell Monitoring Model