After-sales Service: | 1 Year |
---|---|
Warranty: | 1 Year |
Type: | Storage Battery Tester |
Test Region: | Charge and Discharge |
Application: | Lead-acid Battery |
Customized: | Customized |
Customization: |
---|
Suppliers with verified business licenses
Range | Accuracy | Note | |
Volts/Am ps/Hertz |
Volt: 10~700V (true rms) Amps: 0.5~1000A (true rms, with1000A current clamp) N current: 0.5~10A (true rms) Hertz: 40~70Hz |
Volts: ±0.5% Amps: ±0.5% Hertz: ±0.01Hz |
The measuring Hertz is the Hertz of A-phase here. |
Harmonic |
Volts: total harmonic +1~50th Amps: total harmonic +1~50th |
Volts: ±0.1(%r) Amps: ±0.05 (A) |
|
Power testing |
Active Power: 0.05~700KW Apparent Power: 0.05~700KVA Reactive Power: 0.05~700KVAR Power Factor: 0.00~1.00 Active Energy: 0.01~10000kWh Apparent Energy: 0.01~10000kVAh Reactive Energy: 0.01~10000kVARh Average Power Factor: 0.00~1.00 |
Active Power: indication±50W Apparent Power: indication±50VA Reactive Power: indication±50VAR Power Factor: indication±0.05 Active Energy: indication±0.05kWh Apparent Energy: indication±0.1 kVAh Reactive Energy: indication±0.1 kVARh Average Power Factor: indication±0.005 |
|
Unbalance |
Fundamental Volts: 10~700V (true rms) True Amps: 0.5~1000A (True rms) Fundamental Hertz: 40~70Hz Phase Angle: 0~360o Unbalance: 0.0%~100% |
Volts: ±0.5% Amps: ±0.5% Hertz: indication±0.01Hz Phase Angle: indication±0.3 o Volt unbalance: indication ±0.2% |
The measuring Hertz is the Hertz of A-phase here. |
Records | Recordable Parameters: | As relevant items above | Maximum |
3-phase Volts, 3-phase Current, Neutral Current, 1-50th Harmonics (Voltage and Current), Unbalance, Active Power, Power Factor | recording time for one task is 960 hours. | ||
Scope |
3-phase Volts, 4-wire Current, null volt and null current waveform |
Max Hertz: 200KHz Min Hertz: 100Hz |
Abbreviation | Full name | Where are they? |
AVG | average | VOLTS/AMPS/HERTZ |
Amp(s) |
Current |
VOLTS/AMPS/HERTZ, HARMONICS,etc. |
VECT. |
Vector graphic |
VOLTS/AMPS/HERTZ, HARMONICS,etc. |
DET. |
Detailed |
VOLTS/AMPS/HERTZ, HARMONICS,etc. |
TRE. |
Trend |
VOLTS/AMPS/HERTZ, HARMONICS,etc. |
HIST. | Histogram | HARMONICS |
HAR. | harmonic | HARMONICS |
PF | power factor | POWER & ENERGY |
Ne.s. | Negative sequence | UNBALANCE |
Po.s. | Positive sequence | UNBALANCE |
Unbal. | Unbalance | UNBALANCE |
Rec. | record | RECORD |
V | Voltage | RECORD |
CH | channel | SCOPE |
DEL. | delete | SYSTEM-DATA MANAGEMENT |
TO USB | Save in USB drive | SYSTEM-DATA MANAGEMENT |
CALI. | calibration | SYSTEM-SETTINGS |
I | Current | SYSTEM-SETTINGS |
PARA | parameter | SYSTEM-SETTINGS |
PARAM | parameter | SYSTEM-SETTINGS |
TP | touch panel | SYSTEM-SETTINGS |
Rng | range | SYSTEM-SETTINGS |
PT | potential transformer | SYSTEM-SETTINGS |
CT | current transformer | SYSTEM-SETTINGS |
Input Impedance: | 1MΩ,20pF |
Measurement Range: | VRMS 10~700V Arms:1A,10A,100A,1000A(with relative current clamps) |
Frequency | 30Hz~80Hz |
Harmonic Measurement: | 0~50th harmonic Peak Voltage: 1000V |
Internal Memory: | 128MB |
LCD Display: | 320*240 pixel, touch screen Communication Port: USB |
Net weight:
|
7kg |
Suppliers with verified business licenses